Table 1 (from II.B.3.a of GP02, with federal limits interpolated for purpose of comparison) | |||||||
maximum engine HP | engine design | emission standards in g/hp-hr | |||||
NOx | CO | VOC | |||||
Colo. | JJJJ | Colo. | JJJJ | Colo. | JJJJ | ||
.GE. 100 and .LT. 500 | rich burn | 2.0 | 4.0 | 1.0 | |||
lean burn | 2.0 | 4.0 | 1.0 | ||||
.GE. 500 | rich burn | 0.7 | 1.5 | 1.0 | |||
lean burn | 2.0 | 1.5 | 0.7 |
Table 2 (from II.B.3.b of GP02, with federal limits interpolated for purpose of comparison) "State-only Engine Requirements per Regulation No. 7, Section XVII.E. Emissions from natural gas fired reciprocating internal combustion engines that are greater than or equal to 100 hp and constructed in(1) or relocated to the state of Colorado from another state on or after the applicable date, shall not exceed the emission standards in Table 2 . . ." | |||||||
maximum engine HP | construction or relocation date on or after | emission standards in g/hp-hr | |||||
NOx | CO | VOC(2) | |||||
Colo. | JJJJ | Colo. | JJJJ | Colo. | JJJJ | ||
.GE. 100 and .LT. 500 | Jan. 1, 2011 | 1.0 | 2.0 | 0.7 | |||
.GE. 500 | July 1, 2010 | 1.0 | 2.0 | 0.7 |